2.2
(a) Diaphyseal deformity of femur; D100 series fixator in place.
(b) Osteotomy and correction of deformity.
Use of HA-coated screws is recommended.
2.2
(a) Diaphyseal deformity of femur; D100 series fixator in place.
(b) Osteotomy and correction of deformity.
Use of HA-coated screws is recommended.
6.3
Large peripheral bony defect.
(a) LRS Fixator (D200 series) in place.
(b) Two osteotomies performed in the longer bone segment.
(c) Simultaneous proximal transport with both middle clamps moved proximally until gap closed.
Use of HA-coated screws is recommended.
6.3
Large peripheral bony defect.
(a) LRS Fixator (D200 series) in place.
(b) Two osteotomies performed in the longer bone segment.
(c) Simultaneous proximal transport with both middle clamps moved proximally until gap closed.
Use of HA-coated screws is recommended.
6.2
Large central bony defect.
(a) LRS Fixator (D200 series) in place.
(b) Proximal and distal metaphyseal osteotomies performed.
(c) Simultaneous proximal and distal transport until segments meet.
Use of HA-coated screws is recommended.
6.2
Large central bony defect.
(a) LRS Fixator (D200 series) in place.
(b) Proximal and distal metaphyseal osteotomies performed.
(c) Simultaneous proximal and distal transport until segments meet.
Use of HA-coated screws is recommended.
6.1
Large proximal or distal defect, with or without loss of length.
(a) Large distal defect in the femur; LRS Fixator (D200 series) in place. Proximal metaphyseal osteotomy.
(b) Middle segment moved distally until docking occurs.
(c) Optional additional lengthening proximally, if indicated.
Use of HA-coated screws is recommended.
6.1
Large proximal or distal defect, with or without loss of length.
(a) Large distal defect in the femur; LRS Fixator (D200 series) in place. Proximal metaphyseal osteotomy.
(b) Middle segment moved distally until docking occurs.
(c) Optional additional lengthening proximally, if indicated.
Use of HA-coated screws is recommended.
5.1
Varus deformity of the proximal femur following lengthening; the LRS Fixator with the Multiplanar Clamp.
(a) Angular deformity following lengthening.
(b) Acute shortening and correction of deformity by callus manipulation.
Use of HA-coated screws is recommended.
5.1
Varus deformity of the proximal femur following lengthening; the LRS Fixator with the Multiplanar Clamp.
(a) Angular deformity following lengthening.
(b) Acute shortening and correction of deformity by callus manipulation.
Use of HA-coated screws is recommended.
4.1
Proximal varus deformity in a short femur. LRS Fixator with Multiplanar Clamp.
(a) D200 series fixator in place with Multiplanar Clamp proximally; osteotomy performed and initial lengthening by callotasis to stretch soft tissues.
(b) Acute shortening and correction by callus manipulation, and completion of lengthening.
Use of HA-coated screws is recommended.
4.1
Proximal varus deformity in a short femur. LRS Fixator with Multiplanar Clamp.
(a) D200 series fixator in place with Multiplanar Clamp proximally; osteotomy performed and initial lengthening by callotasis to stretch soft tissues.
(b) Acute shortening and correction by callus manipulation, and completion of lengthening.
Use of HA-coated screws is recommended.
3.2
(a) Very short femur. LRS Fixator in place.
(b) Proximal and distal osteotomies.
(c) Simultaneous lengthening at each osteotomy site; middle clamp locked to rail, proximal and distal clamps moved in direction of the arrows.
Inset shows Micrometric Swivelling Clamp which can be used instead of a Straight Clamp at either end for adult applications.
Use of HA-coated screws is recommended.
3.2
(a) Very short femur. LRS Fixator in place.
(b) Proximal and distal osteotomies.
(c) Simultaneous lengthening at each osteotomy site; middle clamp locked to rail, proximal and distal clamps moved in direction of the arrows.
Inset shows Micrometric Swivelling Clamp which can be used instead of a Straight Clamp at either end for adult applications.
Use of HA-coated screws is recommended.
3.1
(a) Short femur; LRS Fixator (D200 series) in place.
(b) Osteotomy.
(c) Monofocal lengthening.
Use of HA-coated screws is recommended.
3.1
(a) Short femur; LRS Fixator (D200 series) in place.
(b) Osteotomy.
(c) Monofocal lengthening.
Use of HA-coated screws is recommended.
2.1
Varus deformity of proximal femur; LRS Fixator with Multiplanar Clamp.
(a) D200 series fixator in place with Multiplanar Clamp proximally; osteotomy performed.
(b) Initial lengthening by Callotasis to stretch soft tissues slowly.
(c) Acute shortening and angular correction by callus manipulation.
Use of HA-coated screws is recommended.
2.1
Varus deformity of proximal femur; LRS Fixator with Multiplanar Clamp.
(a) D200 series fixator in place with Multiplanar Clamp proximally; osteotomy performed.
(b) Initial lengthening by Callotasis to stretch soft tissues slowly.
(c) Acute shortening and angular correction by callus manipulation.
Use of HA-coated screws is recommended.
1.8
Distal femoral fracture stabilized using the D100 series with the B.G.T Clamp distally.
1.8
Distal femoral fracture stabilized using the D100 series with the B.G.T Clamp distally.
1.7
Distal femoral fracture stabilized using the D100 series with the T-Clamp distally.
1.7
Distal femoral fracture stabilized using the D100 series with the T-Clamp distally.
1.6
Distal femoral fracture stabilized using the D100 series with the Metaphyseal Clamp distally( D100 series).
1.6
Distal femoral fracture stabilized using the D100 series with the Metaphyseal Clamp distally( D100 series).